The one thing to get right
There is no cross-reference table here, and that is deliberate. A substitution is decided by four published properties on the sheet, not by a part number that maps one brand to another. Anyone who offers you a one-line equivalence is guessing on your stack.
Mitsubishi and Dynamit Are Two Different Questions
Buyers arrive at this page for two different reasons, and they need two different answers.
The first is a qualified stack: a line, a drill program and a backup layer were set up around an entry material the buyer associates with one of these brands, and purchasing has asked whether it can be replaced on price or availability. The second is a new build: an engineer has seen one of these grades named in a reference design or a competitor's process sheet and wants to know what the category is.
This page does not describe Mitsubishi's or Dynamit Nobel's current products. We do not hold their datasheets, we will not paraphrase them, and a page that restated their specifications would be the least reliable document you read this week. What follows is the other half of the comparison: what we publish, in the same units, so the two sets can be read side by side on your desk.
The Four Properties a Substitution Has to Match
Entry material is not one number. Four properties decide whether a replacement behaves like the incumbent, and a substitution that matches three of them and mismeasures the fourth fails in a way that looks like a process problem.
| Property | What has to match | YUESHAN published figure |
|---|---|---|
| Base alloy and temper | The alloy family and the temper, because hardness and thermal conductivity follow both | AA1100 H18 as the documented plain entry grade; 1050, 1060, 3003 and 3105 available where rigidity or surface needs differ |
| Base gauge and its tolerance | Gauge and the band — a ±0.015 mm sheet and a ±0.01 mm sheet at the same nominal are not the same input | 0.18 ±0.015 mm on the documented grade; other gauges 0.15–0.20 mm confirmed per gauge on the quotation |
| Film chemistry and build | Thermoset or water-soluble, and the film thickness — the two behave differently in humid plants | Thermoset film stable to 220 °C; ≤0.10 mm aluminium base for sub-Ø0.15 mm vias; 30 μm coating on the back-drill grades |
| Flatness and consistency | A measured limit, and whether it holds lot to lot — this is what actually moves residual stub on a back-drill line | ≤0.6% of diagonal on the entry sheet; ±0.005 mm on the aluminium layer of HW600 / HW900 |
Read the table as a checklist, not as a claim of equivalence. Every figure in the third column appears on a linked page with its basis — a TDS revision or a stated case — and can be checked against whatever document you hold for the incumbent grade.
What a Cross-Reference Table Cannot Tell You
A mapping table can only map names. It cannot tell you four things that decide the outcome:
- Whether the incumbent's band is actually held. A competitor's datasheet limit and a competitor's delivered lot are different facts, and only your incoming inspection knows the second one.
- What your smallest hole does. Two sheets that both pass at 0.30 mm can separate completely at 0.15 mm, because film build and base gauge stop being interchangeable at that size.
- What the backup layer contributes. Exit burr is a two-layer result. Changing the entry while keeping a backup board that was qualified around the old entry measures neither material.
- Whether the film survives your climate. Water-soluble films are humidity-sensitive; a plant that runs 70% RH in summer is a different test from the one in the datasheet.
How to Run the Substitution
Three steps, in this order. Skipping the first one is the usual reason a trial produces a conclusion nobody trusts.
| Step | What you do | What it proves |
|---|---|---|
| 1 — Match the paper | Put the incumbent's TDS beside the four properties above and mark every row where the numbers differ by more than your process tolerance | Whether the two products are in the same specification at all. If three rows differ, stop: this is a redesign, not a substitution |
| 2 — Run a qualification lot | Same stack, same drill, same hit count, same smallest hole; change the entry sheet only | Whether the difference shows up on your line, measured against your own baseline |
| 3 — Measure the exit side | Exit burr at the same hit count, plus hole wall and drill breakage, recorded per lot rather than per trial | Whether the result holds. One good lot is a sample; three holding lots is a supply |
Send step 1's marked-up comparison with the enquiry. It is a faster conversation than a request for "something like" a named grade, and it gives the quotation a specification to answer against.
The YUESHAN Range in the Same Position
The products that sit where an entry material of this class sits:
- Plain aluminum entry sheets — AA1100 H18, 0.18 ±0.015 mm, published tolerance ladder and maximum format.
- Coated and lubricated entry sheets — thermoset and water-soluble films, with the microvia decision stated as a limit rather than a preference.
- Back-drill aluminum — HW600 and HW900, ±0.005 mm on the aluminium layer, for controlled-depth work.
- The backup layer underneath — HDF, melamine, UV-cured and phenolic, so the exit side is specified with the entry side rather than after it.
All four lines are documented: an entry sheet TDS and SDS, a backup board TDS, and a document set for the back-drill grades. The document library states exactly what exists for each one, including what it does not cover.
Trademarks and scope
Mitsubishi, Dynamit Nobel and any other named manufacturer's product designations are the trademarks of their respective owners. They are used on this page only to identify the category a buyer is asking about. Nothing here states or implies that YUESHAN material is the same product as theirs, is approved by them, or carries their specification. Any substitution is qualified on your line, against your documents, by your own tests.
Questions buyers ask
Can you supply a drop-in equivalent to a Mitsubishi entry sheet?
We can supply material in the same category and put our published figures beside the incumbent's. Whether it is a drop-in depends on your smallest hole, your climate and your backup layer — three things a supplier cannot see from a part number. The qualification lot settles it.
Do you have a cross-reference table?
No, and we would not trust one. A mapping table between two brands' grades maps names, not tolerances, film builds or delivered consistency. The four-property comparison on this page is what we will answer against.
Which grade should I start from if I do not know the incumbent?
Start from the outcome, not the name: smallest hole, layer count, current exit burr measurement and plant humidity. With those four, the grade shortlist is specific — usually two or three candidates rather than a whole catalogue.
Is a cheaper entry sheet a saving?
Only if the backup layer and the hit count stay where they were. Entry material is one line on the landed-cost sheet; a film that raises breakage or shortens bit life moves the two lines underneath it.
Compare the Individual Families
MGC LE SHEET-type
The lubricated-entry category, the water-soluble choice and what an entry-only brand leaves to a second decision.
Open the comparison →LCOA alternative
The coated-aluminum class read against film stability, coating thickness and cost per hole.
Open the comparison →Alltech alternative
How the same category is specified when the buyer arrives with a distributor's grade.
Open the comparison →Thirty buyer questions
Every recurring procurement question, answered once with a number and a boundary.
Open the answer hub →